The Signal
Phys.org reports microrotor spins at 138 million rpm
A study in Science Advances reports a magnetic microsphere levitated at 4.2 kelvin and rotating at more than 2.3 million revolutions per second. The researchers also used the rotor for cryogenic pressure sensing and a preliminary, narrowband search for axion-like dark matter.

A fast-spinning levitated rotor
A magnetic microsphere suspended by the Meissner effect reached a rotation frequency above 2.3 megahertz, equivalent to 138 million revolutions per minute, in a cryogenic experiment. Phys.org described the result as a record for a levitated spinning micromagnet, while the paper itself reports the rotor's speed and measurements.
Source science.org
Published online on Nov. 6 in Science Advances, the study is titled “Ultrafast Meissner-levitated microrotor.” The paper describes a magnetic microsphere levitated at 4.2 kelvin and reports a damping rate of 4.75 × 10⁻⁷ hertz.
How the rotor was tested
The team levitated magnetic spheres with radii of approximately 30 micrometers in a superconducting lead trap cooled with liquid helium, according to Phys.org. The trap expelled magnetic fields through the Meissner effect, allowing the sphere to float without active position control, the outlet reported.
Magnetic coils accelerated the spheres, and an ultrasensitive superconducting detector tracked their rotation and slowdown, Phys.org reported. The experiments ran at 4.2 kelvin, matching the temperature stated in the study's abstract.
The study measured a damping rate of 4.75 × 10⁻⁷ hertz; Phys.org said the slowdown implied a characteristic speed-decay time of about 24 days. The outlet characterized that damping rate as the lowest measured in a levitated micro- or nanosized object.
For comparison, the outlet reported that an earlier levitated-magnet speed record involved a magnet about half a millimeter in diameter spinning at 38 million revolutions per minute.
Pressure sensing at low temperature
The paper reports that the rotor demonstrated absolute pressure sensing across a wide range at cryogenic temperature, based on friction's linear dependence on gas density. Phys.org reported that the pressure measurements extended down to 10⁻⁸ mbar at 4.2 kelvin.
The outlet said the lowest previously reported operating temperature for a spinning rotor gauge was 77 kelvin. In a separate, slower-running experiment, Phys.org reported, the rotor's magnetic-field sensitivity matched the best previously demonstrated with a nonspinning levitated magnet of similar size.
A preliminary dark-matter search
The researchers also operated the rotor in synchronized mode to detect thermal torque noise and conduct a preliminary, narrowband search for axion-like dark matter, the paper reports. Phys.org reported that the initial search covered only a very narrow frequency range and found no related signatures, while helping set limits on possible interactions with electrons.
The study authors described the measurement as very preliminary and said a more thorough, wideband search was left for future work, according to Phys.org.
Sources
Related stories
- EPFL preprint reports around 67% internal efficiency in millimeter-wave transducer
- Horizon Quantum says multiplexing cuts ZZ crosstalk characterization experiments on a 100-qubit processor from about 5,000 to 7
- Paderborn team demonstrates quantum-dot entanglement swapping
- SQS says quantum nodes are operational in Albuquerque and Mesa
- UB team predicts optical fingerprints for 10 h-BN defects