CryoCMOS multiplexer reports 200-pW operation at 10 mK

A cryogenic CMOS radio-frequency multiplexer was tested at 10 millikelvin with reported static power use of 200 picowatts. The researchers also connected it to superconducting transmon qubits to test input, output and flux-bias signal paths.

CryoCMOS multiplexer reports 200-pW operation at 10 mK

A low-power switch at the qubit plane

A cryogenic CMOS radio-frequency multiplexer operating at 10 millikelvin consumed 200 picowatts of static power in tests reported by researchers in npj Quantum Information. The team also connected the switch to superconducting transmon qubits to assess whether it could route signals without substantially disrupting their coherence.

The device is a single-pole, four-throw switch, built using a commercial 22-nanometre fully depleted silicon-on-insulator process. Its four switch arms route a common radio-frequency connection to one of four output ports; two digital input lines select the path. The authors report that the 200-picowatt result represents a 3,000-fold reduction from their earlier implementation.

Measurements across signal paths

At 10 millikelvin, the multiplexer had less than 2 decibels of insertion loss and more than 30 decibels of isolation across DC to 8 gigahertz, according to the paper. At a supply voltage of 0.55 volts, the researchers measured 200 picowatts of static power. In separate measurements, insertion loss stayed below 3 decibels up to 9.2 gigahertz.

The researchers tested the switch in three configurations: on the input line carrying qubit drive and readout signals, on the readout output line, and on a low-frequency flux-bias line used to tune qubit frequency. For the input-line test, three qubits were measured over approximately 12 hours, with signals routed through the multiplexer or a reference line. The paper reports no systematic reduction in energy-relaxation time, but a small reduction in coherence was observed, corresponding to added dephasing rates of 2 to 5 kilohertz.

Readout and flux tests

On the output line, the team reports median energy-relaxation times of 100 to 200 microseconds and coherence times of 50 to 100 microseconds. Those measurements were comparable to its reference-line results, the authors say. The test shows that the multiplexer could be used to route readout signals while measuring qubit coherence.

For the flux-bias test, the multiplexer remained powered while the researchers measured qubit coherence across different applied flux levels. They report that the measurements showed no detrimental effect from the switch’s low-frequency noise on qubit coherence. The paper says the results support using the device for flux-bias multiplexing as well as for input and output signal routing.

Scope of the approach

The authors frame the near-term use as cryogenic characterization and testing, where devices can be measured sequentially. They caution that time-division multiplexing does not offer a scalable way to operate many qubits simultaneously: its practical value, they write, is mainly in settings where sequential measurements are acceptable.

The work was first submitted to arXiv on March 17, 2026. The researchers describe multiplexing of XY drive lines as possible in principle, but that configuration was not demonstrated in the study.