X-ray reflectometry measures arsenic layers below one nanometer in silicon
A study in npj Quantum Information reports that resonant-contrast X-ray reflectometry can measure the chemical thickness of arsenic dopant layers in silicon. Tests on silicon samples found layers as thin as 0.6 nanometers, while the researchers note limits on the measurement.

Resonant-contrast X-ray reflectometry can measure the chemical thickness of arsenic dopant layers in silicon at below one nanometer, researchers report in a paper published November 11, 2026, in npj Quantum Information. The study says measurements of the layers’ chemical thickness align with earlier estimates of their sub-nanometer electronic thickness.
Source nature.com
Separating the arsenic signal
Silicon-based quantum devices can use ultrathin layers of dopant atoms, and the study examined layers of arsenic embedded in silicon. The researchers scanned X-ray energy around arsenic’s core-level resonances, where its scattering factor changes, and compared reflectometry measurements taken at different energies.
That contrast isolates the arsenic contribution from signals associated with the surrounding silicon and oxide. The paper presents both detailed modeling and a perturbation-based analysis for extracting the layer’s depth and thickness from the reflectometry data.
Measurements and limits
The experiments covered five samples: four containing arsenic-doped silicon layers and one reference sample containing buried oxide. For one arsenic sample, a single-energy analysis estimated a layer thickness of 0.9 ± 0.2 nanometers, while the resonant-contrast analysis estimated 0.6 nanometers, with a reported range of 0.4 to 1.3 nanometers.
A separate analysis that scanned the reflected intensity across the arsenic resonance estimated that same sample’s layer thickness at 1.6 ± 0.5 nanometers. The paper reports that the estimates agree within their uncertainties, but describes the resonant-contrast thickness measurements as upper bounds, limited by the experiment’s high-angle cutoff and noise.
Potential for elemental imaging
The work also used X-ray fluorescence to measure the two-dimensional arsenic density in one sample. The article describes combining reflectometry with X-ray fluorescence imaging as a way to characterize elements in three dimensions without damaging the sample.
The researchers say resonant-contrast reflectometry could also be used on other layered materials, including semiconductor heterostructures and quantum materials. They propose that combining the method with nanoscale X-ray beams could enable imaging patterned dopant structures, such as gates, sources and drains.
Sources
Related stories
- UChicago and Tohoku establish quantum materials research hub
- Four Delft researchers win ERC grant for spin-qubit project
- IonQ says DARPA will test its quantum roadmap on hardware
- MoTe₂ preprint reports about 7.1% photon interference, up to 60% after filtering
- PsiQuantum and AMD expand quantum pact; AMD plans investment